- 作者: 駱仁華; 柴惠珍; 師明哲; 李家琨
- 作者服務機構: 三軍總醫院婦產科﹑醫學研究部
- 中文摘要:
利用溴化氫活化 Sepharose-4B 當作固相免疫吸附體,依抗原競爭性吸附原
理,建立固相?免疫分析法。所測得血清游離型雌三醇濃度,日內及日間精密度分
別為4.8~15.5及4.3~16.6;若與放射免疫分析法所測得的相關係數為0.8465;文
內並比較三十位高危險性妊娠婦女懷孕後期,血清游離型雌三醇摘圖。p - 英文摘要: Serum unconjugated estriol wasmeasured by enzyme immunoassay usingCNBr-adtivated Sephadex-4B as solidphase to separate free and bound formestriol. The intra-day and inter-dayprecision of this method are 4.8-15.5and 4.3-16.6, respectively. Comparewith the radio-immunoassay method,the correlation coefficiency is 0.8465.The concentration pattern of serumunconjugated estriol during differentstages of pregnancy was also described.
- 中文關鍵字: --
- 英文關鍵字: --